The writable terminal is an intended feature, but the launch leaves network binding and authentication to ttyd defaults while creating a shell endpoint. This is a plausible remote shell exposure, so it warrants a warning rather than a publish block.
Static reason
One or more suspicious static signals were detected.
Trigger
When a session starts its ttyd web terminal, which the README says is auto-started per session.
Impact
If ttyd uses its default all-interface bind, a reachable client could connect to the terminal and run commands as the package user's account.
Mechanism
The plugin launches ttyd with --writable, a session shell, and a port in the 7881–8080 range. It reports localhost, but leaves ttyd's bind address and authentication defaults unchanged.
Evidence
dist/index.jsREADME.md~/.boff/vibecontrols/tools/ttyd/tmp/vibe-install-ttyd-<pid>/artifact
Network endpoints1
localhost:<assignedPort> (ports 7881–8080; advertised by the plugin)